Preparing the tool
 Set the working pressure at the pressure regulator of the
compressor to max. 10 bar.
 Check the connection for the pressure hose (4) and the quick
coupler (2) of the pressure hose for foreign matter and soiling and
clean, if necessary.
CAUTION
Damaged hoses can burst and and cause material damage due
to the escaping compressed air.
 Inspect the compressed air system and tool for damage
before connection.
 Connect the tool only to a fully functional compressed air
system.
24
WARNING
Inadvertent firing during connection to the
compressed air supply can result in serious or
even fatal injuries.
 Never direct the tool towards yourself,
other people or animals.
 Empty the magazine before connecting
(see page 41).
WARNING
Damaged hoses can burst and result in
injuries.
 Inspect the compressed air system and
tool for damage before connection.
 Connect the tool only to a fully functional
compressed air system.