Mounting
MAKE THE ELECTRICAL CONNECTIONS
Bracket
Receiver
WARNING: To avoid possible electrical shock, be sure you have turned off the power at
the main circuit panel before wiring.
Follow the steps below to connect the fan to your household wiring. Use the wire
connectors supplied with your fan. Secure the connector with electrical tape. Make sure
there are no loose wire stands or connections.
Fig. 13
WARNING: If your house wires are different colors than referenced in this manual, stop
immediately. A professional electrician is recommended to determine proper wiring.
Step 1. Insert the receiver into the mounting bracket, and keep flat in opposition of
Outlet box
ceiling. (Fig. 13)
White
Black
Green or bare copper
Step 2. Motor to Receiver Electrical Connections: Connect the BLACK wire from the fan
(ground)
to BLACK wire marked "TO MOTOR L" from the receiver. Connect the WHITE wire from
White ("AC IN N")
Black ("AC IN L")
the fan to the WHITE wire marked "TO MOTOR N" from the receiver. Connect the BLUE
wire from the fan to the BLUE wire marked "FOR LIGHT " from the receiver. Secure all
Receiver
the wire connections with the plastic wire connectors provided. (Fig. 14)
Black ("TO MOTOR L")
White ("TO MOTOR N")
Step 3. Remote Receiver to Outlet Box Electrical Connections: Connect the BLACK (hot)
Black (motor)
Ground wire
wire from the ceiling to the BLACK wire marked "AC IN L" from the receiver. Connect
Blue (FOR LIGHT)
the WHITE (Neutral) wire from the ceiling to the WHITE wire marked "AC IN N" from the
White (Neutral)
receiver. Secure all the wire connections with the plastic wire connectors provided.
Blue (FOR LIGHT)
(Fig. 14)
Fig. 14