7.22 Led L27 - Pulse frequency.

7.23 Led L28 - Main current.

Range: 5 ÷ 260 A (art. 369), 330 A (art. 370), 450 A (art.
371). Default: 100 A.

7.24 Led L29 - Base or second level current.

G
B

7.25 Led L30 - Slope down.

7.26 Led L31 - Welding end current (Crater Arc).
rent and is displayed in amperes (A).
Range: 5 ÷ 100%. Default: 10%.

7.27 Led L32 - Post-gas.

7.28 Led L33 - Welding end current (Crater Arc)
time.
40
Is the welding current pulse
frequency.
Range: 0.1 ÷ 2500 Hz.
Default: 1.1 Hz.
Is the welding current in
the single level current pro-
cesses and the main current
in the two levels current
processes.
Is a percentage of the main
current.
The displayed value is in
amperes (A).
Range: 0 ÷ 100%.
Default: 50%.
Is the time in which the cur-
rent reaches the minimum
value or the arc shuts down.
Range: 0.0 ÷ 10.0 s.
Default: 0.0s.
This current setting is used
particularly for closing the
final crater.
The value is expressed as a
percentage of the main cur-
Is the gas output time after
welding end.
Range: 0.0 ÷ 25.0 s.
Default: 10.0 s.
Is the welding end current
duration.
Range: 0.0 ÷ 30.0 s.
Default: 0.0 s.

7.29 Led L34 - Spot.

7.30 Led L35 - PLU function (Plasma Unit).
Indicates that the PLU function in the "Second
Functions" menu for the Plasma Welding Con-
sole operation is enabled.
7.31 Led L36 - FdU function (Feeder Unit).
Indicates that the FdU function in the "Second
Functions" menu for the Cool Wire Feeder Unit
operation is enabled.

7.32 Led L37 - rob function (Robot).

Indicates that the rob function in the "Second
Functions" menu for the operation of the Power
Source connected to the Robot Control is enabled.
7.33 Led L40 - ACMix function.
Indicates that the ACMix function in the "Sec-
ond Functions" menu, which provides features
TIG-DC alternating with stretches of TIG-AC, is enabled
(see par. 10.5).
7.34 Led L41 - Dangerous voltage.
In TIG-AC indicates, when lit, the corrected
operation of the device that reduce the risk of
electric shocks.
7.35 Led L42 - Start.
"Hot-Start" level to maximize starts in TIG-AC
mode for each electrode diameter.
When this led lights D2 shows a numerical value
that refers to the electrode diameters.
The operator may use M1 to set the diameter being used to
obtain a good start.
Range: 0,5 ÷ 4.8. Default: 1.6.
7.36 Led L43 - Wave.
Selects the welding current waveform.
When this led lights D2 shows a number corre-
sponding to the selected waveform (see table).
11 = square - square
33 = delta - delta
13 = square - delta
21 = sine - square
31 = delta - square
Default = square - sine (12).
The selection of the waveform may be changed using M1.
Welding time in spot mode
(not available).
22 = sine - sine
12 = square - sine
23 = sine - delta
32 = delta - sine
3300036-C