10.14.9 t2 parameter.
Indicates the duration of the second current (level mode
only), expressed in s.
Range: OFF – 0.1 ÷ 30.0. Default: OFF.
10.14.10 LIM parameter.
Indicates the extension of the current levels range up to 400%.
Selection: OFF – On. Default: OFF.
10.14.11 UdJ function.
Enables the Job selection using the Up/Down buttons of
the torch, with the "Roll" mode selection.
Selection: OFF – 1 – 2. Default: OFF.
− OFF = selection disabled;
1
= selection enabled without Roll mode;
2
= selection enabled with Roll mode.
10.14.12 LOC function.
Enable the Control Panel lock to prevent unwanted chang-
es.
Selection: OFF – 1 – 2. Default: OFF.
− OFF = unlocked, Control Panel operative;
G
1
= total block, Control Panel not operative;
B
2
= partial block, remains enabled only the current
adjustment and the selection of the current graph
parameters (L22 ÷ L34) only for values view.
10.14.13 UM function.
Select the measure unit for the electrode diameter (only
in AC).
Selection: MEt – EnG. Default: MEt.
− MEt = diameter in mm;
− EnG = diameter in inches.
10.14.14 UtC function (Coordinated Universal Time).
Time Zone setting, expressed in hours (h).
Range: -12 ÷ +12. Default: 1.
10.14.15 dSt function (Daylight Saving Time).
Daylight Saving Time setting, expressed in hours (h).
Selection: 0 - 1. Default: 1.
0
= solar time;
1
= daylight saving time.
10.14.16 CAn function.
CAN bus communication line CAN-2 (CN2) setting.
Selection: OFF – MSt – SL. Default: MSt.
− OFF = CAN-2 disabled. In case of Power Source
manual operation, which does not require con-
nection to the CNC of the automated plant (Ro-
bot).
− MSt = (Master). The Power Source is the Master
node.
In case of Power Source connected to the Robot
CNC via Cebora Robot Interface.
46
− SL
= (Slave). The Power Source is the Slave node.
In case of Power Source directly connected to
the Robot CNC, without Cebora Robot Interface.
With the CAn function set on Slave become available the
following parameters:
− Cbr
baud rate selection.
Selection: 125, 250, 500, 1000 kbps.
Default: 125.
− CId
Power Source ID node.
Selection: 1 ÷ 126. Default: 10.
− CMI Robot CNC ID node.
Selection: 0 ÷ 126. Default: 0.
Press simultaneously T7 and T1 to exit the "Technical
Menu" saving current settings.
11

ADVANCED SETTINGS.

11.1 Overview.

The Power Sources are preset from the factory to be
inserted into plants with a lay-out similar to that of fig. 2.
This system configuration covers the majority of
applications, but not all, for this reason the following
guidance is given on how to set up Power Sources to
operate in specific system configurations, different from
that of fig. 2.
NOTE
Is left to the installer assessment and responsibility about
the need to change the factory setting.
If in doubt, contact the Cebora Technical Service.
11.2 CAN-1 and CAN-2 CAN bus lines setup.
The CAN-1 and CAN-2 lines must be configured according
to the plant layout.
During installation, it is advisable to check:
− CAN bus lines power supply;
− line terminating resistors insertion;
− Technical menu "CAn Function" parameters setting
(par. 10.14.16).
NOTE
The line terminating resistors should be inserted only in
equipment placed at the beginning and the end of the CAN
bus line.
In the example of fig. 2:
− for the CAN-1 line, in the Control Panel (24) and in the
Wire Feeder Unit (8). The Power Source (21) is located
in the middle of the line and therefore must have the
line terminating resistors not inserted;
− for the CAN-2 line, in the Power Source (21) and in the
Robot Interface (25), if present, or in the Robot Con-
trol.