Descargar Imprimir esta página

aldes T.Flow Hygro+ Instrucción De Instalación página 51

Publicidad

Idiomas disponibles

Idiomas disponibles

*Dual tariff cabling: In this case, a second 230 V supply must be created to the water heater to bring in the off-peak signal (if
this is tricky, the EDF signal can be replaced by a timer programmed for the pricing structure in force on the site in question).
The dry peak/off-peak contact should be connected to terminals 4 and 5 on the terminal block solely for a dual tariff pricing
structure.
The product will automatically detect the presence of dual tariff (no need to plan for configuration) and will optimise its
operation after a learning period (over 24 hours) of peak/off-peak times.
Note:
- Every time the power is cut off, the product re-learns the structure over the first 24 hours. It operates on a single tariff during
this learning period.
- In the case of an EDF contract with TEMPO (time delay) or EJP (peak load reduction) OPTION: do not make a dual tariff
connection.
Electric wiring diagrams to be provided for depending on the type of pricing structure:
Identical for T.Flow
Nano
®
Electric meter
protected
2x1.5 mm²
Electric contact
Electric meter
2x1.5 mm²
Electric contact
Power
protected
by RCD
30mA
N
16A
N
Distribution panel
Power
by RCD
30mA
N
N
2A
16A
A1 A2
N
N
Day/night power
Distribution panel
Power
protected
by RCD
30mA
N
N
16A
2A
N
N
Day/night power
2x1.5 mm²
Distribution panel
L
N 4
5
Water heater
off-peak hours
contact
L
N 4
5
Water heater
2x1.5 mm²
L
N 4
5
Water heater
51
Single tariff
connection
Dual tariff 1 connection
with off-peak hours contact
Dual tariff 2 connection without
off-peak hours contact
EN

Publicidad

loading

Este manual también es adecuado para:

T.flow nano