9.2 Technical programming

9.2.1. For ME: COMPACT -
models
9.2.1.1 Selection of the water level probe
sensitivity mode
It is possible to select the water level probe sensitivity
mode (LOW, MEDIUM and HIGH) directly from the
keypad. To do so, act as follows:
● LOW sensitivity mode (200Kohm):
starting from the machine OFF status, power up
the machine by holding both keys A and E pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.
● MEDIUM sensitivity mode (400Kohm):
starting from the machine OFF status, power up
the machine by holding both keys B and E pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.
● HIGH sensitivity mode (1Mohm):
starting from the machine OFF status, power up
the machine by holding both keys C and E pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.
84
All manuals and user guides at all-guides.com

9.2.1.2 Selection of fill-up time-out

PLUS
It is possible to set the time-out interval (120, 180 or
240 sec options provided) directly via the keypad. To
do so, act as follows:
●Time-out 120 seconds:
● Time-out 180 seconds:
● Time-out 240 seconds:
starting from the machine OFF status, power up
the machine by holding both keys A and D pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.
starting from the machine OFF status, power up
the machine by holding both keys B and D pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.
starting from the machine OFF status, power up
the machine by holding both keys C and D pres-
sed in simultaneously. The right sensitivity mode
is signalled by the respective LEDs lighting up.
Switch the system off then switch it back on again
to reset the machine's standard operations.