This default parameter is set at 0, it is changed in the
case of machines with steam probe (TS) as it enables
use of key 6 (fig. 7) on one of the pushbutton panels
for TS activation.
Possible setting parameters are:
0
Normal utilisation without TS
1 Utilisation key 6 (fig. 7) of pushbutton panel of the
first unit on the left
2 Utilisation key 6 (fig.7) of pushbutton panel of the
second unit on the left
3 Utilisation key 6 (fig.7) of pushbutton panel of the
third unit on the left
Press E to confirm and continue to the next menu.
Display indicates
PreBrewing
ENABLED/DISABLED
To activate and disable pre-infusion press A and B.
In the case of activation, press E to continue to pre-
infusion ON and OFF settings for every type of coffee,
press A and B to set the values.
Press E again and continue to the next menu
Display indicates
ProbeSensitivity
- - - - - - -
To select level sensitivity press A and B.
This is set according to the content of mineral salts
in the water of the network utilised.
If the water utilised has a low salt content, set a high
level of sensitivity, if the salt content is high, the low
level of sensitivity will have to be set.
LOW sensitivity
150kW (low)
MID sensitivity
400KW (mid)
HIGH sensitivity
1MW (high)
Press E to confirm and continue to the next menu.
Display indicates
Service Cycles
- - - - - - -
To set the number of cycles that can be carried out
(supplies permitted) press A and B.
where ----
can be a number between 0000
to 99000 at steps of 1000
when ----
equal to 0000 function is disabled.
All manuals and user guides at all-guides.com
Press E to confirm and continue to the next menu.
Display indicates
Temperature
°C/°F
To set the temperature at C° or F° press A and B,
press E to confirm and continue to next the menu.
Display indicates
Boiler Temperat.
- - - -
Setting of boiler temperature is carried out by means
of a temperature probe.
By acting on keys A and B it is possible to set the
required temperature, which can range from 80 to
120 °C.
Press E to confirm and continue to the next menu.
Display indicates
FillingUp T-Out
- - - -
Press A and B to set the maximum time of continuous
pump operation. Should the pump be in operation
for longer than the time set, the machine will give a
warning signal.
N.B. Default time set is 120 secs. It is advisable not
to exceed this value as the pump could overheat.
Once the value has been set, press E to confirm and
continue to the next menu.
Display indicates
Water Filter
- - - -
Press A and B to set softening filter litres, the field
to be set is a value that can be selected between 0
÷ 5000 liter.
Press E to confirm and quit the technical program-
ming menu.
N.B. Once in the technical programming environment,
to quit press E and run along all the menus.
87