Ultimatte will respond with an ACK message followed by either a GPI List Block or a
Message Block.
GPI LIST: ↵
ID: 1 ↵
Index: 0 ↵
File 1 ↵
File 2 ↵
...
↵
or
MESSAGE: ↵
Warning: Event limit exceeded ↵
↵
Frame Buffer
The client may request that the Ultimatte device assign a pre-loaded image from its Media Pool
into a particular frame buffer and enable/disable the frame buffer. To assign and enable an
image to the BG frame buffer the following commands are required:
FRAME BUFFER: ↵
BG 1 Frame Buffer Index: 1 ↵
BG 1 Frame Buffer Enable: on ↵
↵
To disable the frame buffer only the enable command is required:
FRAME BUFFER: ↵
BG 1 Frame Buffer Enable: on ↵
↵
NOTE
The Telnet interface does not currently provide loading or removing images
in the Media Pool. This has to be done from either a Smart Remote 4, or using the
Software Control application. Refer to the 'using the media pool' section of this manual
for more information.
Camera Control
Ultimatte 12 HD Mini can be used to control an attached camera via SDI or HDMI, please refer
to the 'Camera Control via Ultimatte 12 HD Mini' section for more information. For SDI Camera
Control, the Ultimatte device's Camera ID may be changed using the CAMERACONTROL block:
CAMERACONTROL: ↵
Camera Id: 1 ↵
↵
NOTE
This control block is only available on the Ultimatte 12 HD Mini.
Developer Information
1111