6.3.3 AUTOMATIC CYCLE 65°
Fig.1
Fig.2
Fig.3
Fig.4
- Press the AUTOMATIC 65° key to start the
automatic heating cycle at 65° and subsequent
maintenance for 30'. The key LED such as on and
the instantaneous temperature of the product in
tank during the entire processing cycle is shown on
display (fig.1-2).
- Once the temperature of 65° is reached and 30'
standby time has passed, the display flashes and
the buzzer sounds intermittently, to inform the
operator that the mixture can be extracted (fig.3). If
this is not possible right away, the beater will keep
on mixing and the electrical heat element will hold
the mixture at the correct temperature, thus starting
the PRESERVATION phase without limits of time.
- During the preservation phase, the temperature of
the product in tank flashes on the display.
- It is possible to go to the product extraction phase
at any time (fig.3).
At any moment, it is possible to verify the
instantaneous temperature value of the bain-marie
fluid by keeping the AUTOMATIC 65° key pressed
for at least 3" (fig.4). This value will be displayed for
about 10".
ENGLISH - 18