7.
Maintenance
!
Do not use abrasive detergents, solvents (petrol,
diesel, etc.) and rough workshop rags to clean the
station. Clean only with a soft cloth and a neutral
detergent.
i
In case of refrigerant leaks during normal use of the
machine and during installation, maintenance or
repair of the machine, no refund will be made by the
manufacturer.
CAUTION: disconnect the power supply
before any maintenance operation.
7.1
Maintenance program
WARNING: to prevent accidents, only
qualified personnel must perform
inspections and repairs on the station. Read
and follow the instructions and warnings in
this manual. Wear protective clothing that
include safety glasses and gloves.
Maintenance operation
Recommended interval
Filter replacement
The filter must be replaced after
150 kg (331 lb) of refrigerant
has been filtered. See Filter
Maintenance in the Maintenance
section of this manual.
Vacuum pump oil change When the filter is replaced or every
100 hours. See vacuum pump oil
change in the Maintenance section
of this manual.
Checking the correct
Every month.
operation of wheels and
rollers
Checking the internal
Every month. See Checking the
scale calibration
calibration in the Maintenance
section of this manual. Every year,
all scales must be calibrated by an
authorized Bosch service center.
Setting to zero of PAG
Whenever necessary. See Scale
and POE oil injection, oil
Reset in the Maintenance section of
drain and UV dye scales
this manual.
Leak check
Automatic every 10 days. See Leak
Check in the Maintenance section of
this manual
Cleaning the air suction
Every month. Use a clean cloth.
panels
Cleaning the panel and
Every month. Use a clean cloth.
control panel
Inspection of the
Everyday.
integrity of the power
cable and hoses
Lubrication of wheel
Every month.
bearings and inspection
of brake components
Inspection of solenoid
Every year - performed by an
valves
authorized Bosch service center.
Robert Bosch GmbH
Maintenance | ACS 763/863 | 73
Maintenance operation
Recommended interval
Internal refrigerant
Everyday.
analyzer filter check
(only for ACS 863)
Filter change and internal
Every six months or whenever it
refrigerant analyzer
is dirty and/or clogged. Replace
pick-up hose (only for
the pick-up hose every the filter is
ACS 863)
replaced. See internal refrigerant
analyzer maintenance in the
Maintenance section of this manual.
7.2
Spare parts
CAUTION: to prevent accidents, for repairs
use only the components included in
the spare parts list as these have been
carefully tested and selected by Bosch.
Replacement component
Calibration weight
Filter
Oil drain tank
PAG oil injection tank
POE oil injection tank
UV dye tank
Printer paper (5 rolls)
Low pressure service connection
High pressure service connection
Low pressure service connection
(only for ACS 863-OE)
High pressure service connection
(only for ACS 863-OE)
Service hose (low pressure, blue)
Service hose (high pressure, red)
Tank Adapter (1234 <22 HW) + Gaskets
Tank Adapter (1234 DNT) + Gaskets
Tank Adapter (1234> 22 HW) + Gaskets
Vacuum pump oil (600 ml)
Refrigerant analyzer filter
(only for ACS 863)
Refrigerant analyzer pick-up hose
(only for ACS 863)
en
Code
SP01100095
SP01100355
SP00101727
SP00101414
SP00101412
SP00101418
SP00100087
SP01100525
SP01100524
SP01100506
SP01100507
SP00101644
SP00101643
SP01100352
SP01100353
SP01100354
SP00100086
SP00101646
SP00101645
|
SP00D00490
2019-03-05