76 | ACS 763/863 | Maintenance
7.7
Internal refrigerant analyzer
maintenance (only for ACS 863)
This device analyzes a sample of refrigerant flowing into
the internal tank to check that it is
contaminated. Replace the refrigerant analyzer pick-up
hose every time the filter is replaced and when an error
message appears on the display indicating the clogged
hose.
1. Turn off the station.
2. Open the rear service door.
3. Remove the rear cover (above the service door)
pushing it up and pulling it out to remove it.
1
2
Fig. 24:
Internal refrigerant analyzer maintenance
1 Filter
2 Pick-up hose
4. Disconnect the pick-up hose, located between the
rear of the manifold and the refrigerant analyzer, and
install a new hose.
i
If the filter is of any color other than white, replace it.
5. Pull the filter out of the brackets while
disconnecting its connections from the rubber
fittings.
6. Install a new filter with the down arrow, as
indicated on the refrigerant analyzer. Push the filter
connections into the rubber fittings.
7. Insert the rear cover so that the 4 holes on the sides
of the cover fit into the 4 tabs on the station. Push
down to hook the rear cover.
8. Close the rear service door.
|
SP00D00490
2019-03-05
7.8
This function is used to ensure that the station internal
balance is always calibrated. During this test, use only
and is not
the calibration weight supplied with the station.
R1234yf
1. Check that the magnet on the bottom of the station
2. Call up the Main Menu.
3. Select
4. Select
5. Select Maintenance.
6. Select Calibration Check.
7. Fix the calibration weight to the magnet at the
Fig. 25:
1 Magnet
8. Select
9. Remove the calibration weight from the magnet.
10. Select
+
+
Calibration check
is clean.
.
.
« The display shows
Place the calibration
weight on the magnet located at the
bottom of the machine
bottom of the machine.
1
Calibration check
to continue.
« The display shows
Remove the calibration weight from
the magnet located at the bottom of
the machine
to continue.
If
display, the scale is calibrated. Select
to the Maintenance Menu.
If
Unsuccessful calibration
scale is not calibrated. Select
calibration continues to be unsuccessful, contact an
authorized Bosch service center.
is displayed on the
to return
is displayed, the
to try again. If the
Robert Bosch GmbH