8.2.2 Welding station
The unit may provide its maximum output current for a limited period of time only, after which it must be allowed to cool down. This
is the operation and overheating factor given on the identification plate for the welding generator.
This identification plate for the unit is based on a period of 10 minutes and shows a percentage of time during which the unit can be
used for welding at the nominal welding current value before it starts to overheat or before welding will cut out.
Operation and overheating factor
60 % intensive
35 % normal
6 minutes of welding
During extended periods of welding at high currents, the thermal protective device will be triggered. Wait a few minutes for it to
automatically reset before resuming welding.
Always respect the operation and overheating factor given on the identification plate for the welding generator.
If used frequently above its rated load, the unit will wear out quickly. Damage caused in this way will not be
covered by the warranty.
IMPORTANT
8.3
Identifying the welding set
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(B)
(C)
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
....../.............. - ........................... - .........
8.4
Specifications
8.4.1 Generating set
Model
Rated output
Acoustic pressure level at 1 m/measurement uncertainty
Engine type
Recommended fuel/fuel tank capacity
Recommended oil/oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Spark plug type
Dimensions l x w x h
Weight (without fuel)
o: standard
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the
event of an overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
8.4.2 Welding station
Welding data
Priming voltage
Welding ranges
Normal duty cycle (35%)
Intensive duty cycle (60%)
Min rod diameter
Max rod diameter
Example for an operation and overheating factor of 60%:
(A)
(E)
(F)
(G)
(H)
(K)
(I)
(M)
Welding current
170 A
200 A
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
(D)
power level
(J)
(D):
Welding speed
(E):
Maximum power
(L)
(F):
Current amperage
Engine manufacturer:(e.g.
Kohler)
........................................
X: not available
22/144
Max. priming voltage
75 V
4 minutes switched off
(G):
Power factor
(H):
Current frequency
(I):
Ground
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
Engine serial number: (e.g Kohler (SERIAL
NO. 4001200908))
......................................................
VXC 200/4 C5
4800 W
86 dB(A)/0,7 dB(A)
GX390
Unleaded petrol/6,1 L
10W30/1,1 L
O
X
230V-20,9A
O
2 x 2P+T- 230V-10/16A
330830005
87 x 57 x 55,5 cm
86 kg
75 V
40-200 A
200 A
170 A
1,6 mm
4 mm