is shown on the display.
8A. Press the
button to start the cycle.
The tyre is infl ated to a pressure 60% higher than the set value (within maximum pressure
limits). Once the overinfl ate pressure is reached, the system defl ates the tyre to reach the
set value. The pressure is not displayed until the entire infl ation and defl ation cycle is com-
plete, and three horizontal red bars are shown instead of the value together with a fl ashing
triangle (Fig. 51c).
Once the cycle is complete, the pressure is displayed again in green and the fl ashing green
triangle disappears (Fig. 51d).
At this stage, infl ation has ended.
9A. Disconnect the Doyfe infl ation fi tting from the wheel.
10A. Fit the inner core of the valve (Fig. 51a).
Note: Press the "STOP" button
to stop the
automatic infl ation cycle at any time.
- The error message A08 ERR_STP is shown on the
display (see Fig. 51e).
51e
- Press the
button to exit the INFLATRON
function and e return to the main screen.
6.1.b Error messages
UK
In the event of anomalies, error messages will appear on the display, and all valves will
be closed.
A01
Loss of calibration coeffi cients.
- If the problem persists, contact the technical assistance.
A06
Tubeless procedure or overinfl ation selected.
- Carry out defl ation, when necessary.
A08
Operation stopped with the stop key.
A10
The pressure has not increased after several attempts.
Hose not connected
- connect the disconnected hose.
User manual S 1000
181