Descargar Imprimir esta página

SICE S 1000 Manual De Instrucciones página 193

Ocultar thumbs Ver también para S 1000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8.
TROUBLE SHOOTING
In the event of a temporary mains power loss with the MOUNTING/DEMOUNTING tool
between the wheel and the tyre, proceed as follows once mains power has been restored:
- Restart the machine
- Press the RESET button on the display
The machine resumes operation normally from
where it was stopped, remembering the position
of the tools and wheel.
In the event of a prolonged electrical power out-
age, the wheel may be released manually by in-
serting an 8 mm diameter steel pin in the relative
hole and turning anticlockwise (see Fig. 57)
ERRORS LIST
ERRORS
E2
Communication software error
E17
Check serial connection between P3K
and board
E19
Pump motor protection
E20
Perform machine calibration
E23
Motor overload circuit breaker tripped
during wheel clamping
E24
Motor overload circuit breaker tripped
during wheel unclamping
E35
Lifter not in working position
E36
No wheel in the memory
E38
Wheel not saved
E45
Turntable translation potentiometer
not detected
E46
Upper carriage potentiometer not
detected
E47
Lower carriage potentiometer not
detected
E60
Wait for positioning
E64
Error in p3k fi rmware
User manual S 1000
SOLUTION
Press OK to restart
Contact support service
Contact technical support if error persists
Contact technical support for the
calibration
Contact technical support if error persists
Contact technical support if error persists
Reposition, then repeat the command
Repeat the command
Contact support service
Pass to manual mode
Pass to manual mode
Update p3k fi rmware again
57
UK
193

Publicidad

loading