9.7
Filtration
1 filter must be installed on the pump suction line, positioned as indicated in Fig. 7 and Fig. 7/a.
With fluid at ambient temperature
Inlet
Supply tank
With fluid at high temperature max. 85° C
Inlet
Supply tank
The filter, which is to be installed as close to the pump as
possible, must be easy to inspect and have the following
specifications:
1. Minimum flow rate at least 3 times the nominal flow rate
of the pump.
2. Inlet/outlet port diameters no smaller than the inlet port
diameter of the pump.
3. Filtration grade between 200 and 360 µm.
1 Filter 1
2 Plunger pump
3 Pressure gauge
4 Safety valve
5 Manual control valve
Bypass
1 Filter
2 Booster Pump
3 Pressure gauge
4 Pressure switch
5 Plunger pump
Bypass
For smooth pump operation, regular filter
cleaning is necessary, planned according to the
actual use of the pump in relation to the quality
of water used and actual clogging conditions.
32
6 Pressure gauge
7 Safety valve
8 Manual control valve
Fig. 7
Fig. 7/a