Switching contact
Downgrade status
status
open
Downgrade active
closed
Downgrade inactive
The configuration tool is required to change the lo-
gic of the downgrade input.
1 "6.5.1 Description of the configuration tool"
[} 28]
Electrical connection of the switching contact
ATTENTION
Material damage due to improper installation
Improper installation of the switching contact can
damage the product or lead to malfunctions. Ob-
serve the following requirements during the install-
ation:
u Select suitable cable routing to avoid interfer-
ence.
In the delivery state, a jumper is inserted on the
downgrade input. This must be removed first.
Fig. 12: Removing the jumper
u Remove the jumper.
12 V DC, 8 mA
Downgrade input
Fig. 13: Schematic circuit diagram: Connection of an
external switching contact (default setting: NC)
20
XG1
3
NC
NO
4
u Install external switching contact.
u Strip the cable.
u Strip the conductors 10 mm.
u Connect the conductors to terminals 3 and 4
(XG1).
u Comply with the connection data for the down-
grade input.
1 "4 Technical data" [} 10]
Configuration
The reduced charging current, which is applied
when the switching contact at the downgrade input
is energised, can be set via DIP switches 4 and 5
on bank S2. The charging current is reduced on a
percentage basis depending on the set maximum
charging current.
DIP switch
Percent-
setting (bank
age of
S2)
max. char-
ging cur-
4
5
rent
OFF
OFF
0 %
OFF
ON
25 %
ON
OFF
50 %
ON
ON
75 %
* At least 6 A are always available for the charging
process. If the calculated reduced charge current is
less than 6 A, it is rounded up.
6.2.2 Blackout protection
The tasks described in this section may only
be carried out by a qualified electrician.
To prevent an overload at the building connection
with a charging point (blackout protection), it is ne-
cessary to record the current values ​ ​ f rom the build-
ing connection with an additional external energy
meter. The energy meter also takes account of
other consumers in the building. Blackout protec-
tion is not possible in the case of building connec-
tions with more than 63 A.
Reduced charging
current (example:
max. charging cur-
rent = 10 A)
0 A
6 A *
6 A *
7.5 A *