The following advanced settings can be made:
n Perform firmware update
n Change the default setting (20 A) for the unbal-
anced load limitation (possible values:
10 A ... 30 A)
n Deactivate acoustic feedback
n Deactivate Sleep mode (for reduced standby
consumption of approx. 1 W)
n Activate undervoltage / overvoltage detection
for the connected phases and set the respect-
ive limit values
n Import and export settings
n Change the logic of the downgrade input (de-
fault: downgrade is active when the switching
contact is open)
n Specify the energy meter measuring point for
blackout protection and solar charging (default:
energy meter measures external consumers
and charging station (total consumption))
n Change the minimum solar charging current in
Sunshine+ mode (default: 6 A)
n Managing RFID cards
n Deactivate the wake-up function ("waking up" of
vehicle so that a charging process can be con-
tinued)
n Set fallback current for connecting to an energy
management system (default: 0 A)
In addition, the current operating values are dis-
played and the DIP switch settings are explained in
the configuration tool. Should a fault occur, the con-
figuration tool offers assistance with troubleshoot-
ing (fault message, log file).
To use the configuration tool, the MEN-
NEKES configuration cable is required. You
can find the MENNEKES configuration cable
(order number 18625) on our website under
"Products" > "Accessories". You can also
download the configuration tool and in-
struction manual there.
1 "1.1 Website" [
 2]
}
The instruction manual for the configuration tool
describes how to install and use the tool.
1 Comply with the configuration tool manual.
6.5.2 Managing RFID cards
ü Requirement: No charging process is in pro-
gress.
Adding or removing RFID card(s) to/from the
whitelist
The master RFID card can be used to add new RFID
cards to the internal whitelist or to remove them
from it.
u Hold the RFID card in front of the RFID card
reader to activate Teach mode.
ð The "Sun" LED flashes.
u Hold RFID cards in front of the RFID card
reader.
ð If the RFID card has not yet been included in the
whitelist, it will be added to the whitelist, and
the "Standby" LED flashes once.
ð If the RFID card has already been included in
the whitelist, it will be removed from the whitel-
ist, and the "Fault" LED flashes once.
ð If 10 RFID cards have already been included in
the whitelist, the whitelist is filled to capacity,
and the "Fault" LED flashes three times.
n Teach mode will end after 60 second
and the "Sun" LED goes back to indicate
the set status.
n The master RFID card cannot be used to
authorise charging processes.
Programming a master RFID card
The DIP switches 1, 2 and 3 on bank S2 are
mainly needed to set the maximum char-
ging current.
Exception: If all three DIP switches are set
to "ON", a new master RFID card can be
programmed. The product indicates the op-
erating state "Fault".
EN
29