Push the piston guides forward with their con-rods to
facilitate side extraction of the pump shaft. There are two
reference points visible on the shaft (indicated with 1 in
Fig. 4 and in Fig. 4/a). These must be turned toward the
operator to facilitate extraction.
-
Remove the pump shaft
-
Complete disassembly of the con-rod units by removing
them from the pump casing and removing the piston
guide pins.
-
Remove the pump shaft seal rings using common tools.
-
Remove the piston guide seal rings as described below:
Use the extractor code 26019400 (Fig. 5, pos. ) and the
gripper code 27503900 (Fig. 5, pos. ). Insert the gripper as
far as possible onto the seal ring with the aid of a hammer
(Fig. 5/a), subsequently screwing the extractor to the gripper,
and use the extractor hammer (Fig. 5/b) until the ring to be
replaced is removed (Fig. 5/c).
Fig. 4
Fig. 4/a
When disassembling the con-rod groups check the wear
status of the piston guide rods (pos. , Fig. 5/d), if necessary
replace them removing the 2 fixing M6 screws (pos. ,
Fig. 5/d).
Fig. 5
16
Fig. 5/a
Fig. 5/b
Fig. 5/c