Descargar Imprimir esta página

Interpump Group SWS71 Manual De Reparación página 21

Ocultar thumbs Ver también para SWS71:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
-
Disassemble the suction and outlet valve units, screwing a
sufficiently long M10 screw in such a way as to be able to
reach the valve plate and extract the valve guide from the
valve seat (pos. „, Fig. 17).
2.2.2
Reassembly of the head - valve units
Pay particular attention to the conditions of the
various components and replace if necessary,
and at the intervals indicated in the "PREVENTIVE
MAINTENANCE" table in the use and maintenance
manual.
At every valve inspection, replace all O-rings and
all anti-extrusion rings both in the valve units
and on the valve plugs.
Before repositioning the valve units, thoroughly
clean and dry the relative seats in the head as shown
in Fig. 18.
To reassemble the various components, perform the
operations listed above in reverse order to par. 2.2.1. To
facilitate insertion of the valve guide in its housing, you can
use a bush resting on the horizontal guide planes and use a
hammer acting on the whole circumference (Fig. 19/a).
code 26019400
code 27516900
Fig. 16/b
Fig. 17
Fig. 18
21
Do not invert the suction springs with the
previously disassembled outlet springs during
assembly of the suction and outlet valve units:
A) "White" suction springs.
B) "Black" outlet springs.
Insert the suction and outlet valve units,
checking that they are fully inserted in the head
seat.
Then apply the valve covers and calibrate the
respective M12x35 screws torque wrench at the
required tightening torque
Fig. 19
Fig. 19/a
Fig. 19/b

Publicidad

loading

Este manual también es adecuado para:

Ss71Sn71Sw71