2. How to use
Automatic / Treatment
Two functions can be selected in this menu. The automatic function measures either
the time in seconds via the "Timer" function or the flow rate of the heated water in
litres via the "Filling volume" function. Cold water mixed in at the fitting cannot be
EN
detected by the unit. For correct use of the automatic function according to filling
volume, it is therefore necessary to set the desired temperature on the unit and only
open the hot water valve on the fitting.
Timer
Set the desired time under "Duration" and then tap "Timer" to activate the automatic
function. The view changes to the main control in which the set time is displayed
directly below the temperature display.
Opening the hot water tap starts the function and the time starts running every sec-
ond. If hot water is already flowing when the function is activated, it starts immedi-
ately.
To cancel the function, the time must be touched and the prompt confirmed.
When the time has elapsed, the flow rate, if tapped, is reduced for about 10 seconds
and then increased again.
Note: The behaviour of the timer can be changed in the configuration.
Tub filling
Set the desired amount of water under "Filling volume" and then tap on "Tub filling" to
activate the automatic system. The view changes to the main control where the set
quantity is displayed directly below the temperature display. Turning on the hot water
tap starts the function and the set fill quantity counts down in litre increments accord-
ing to the flow measurement.
Continued turning off and on of the tap pauses and restarts the function. If hot water
is already flowing whilst the function is activated, it starts immediately. To cancel the
function, touch the fill quantity for three seconds or turn off the water flow for a min-
ute.
When the fill quantity is reached, "0 l" flashes briefly on the display and the appliance
stops the water flow by closing the motor valve. A long acoustic signal can also be
heard and an instruction message appears on the display. The motor valve stay closed
until the message is confirmed at the appliance or via app.
Turning off the tap is always necessary, the function must therefore not be used unsu-
pervised.
Before using the bath, make sure that the water temperature is what you want it to be.
Hint: The water amount of the last draw-off is stored in the "Statistics" menu. To
determine the necessary amount of water for your bathtub, fill it with warm water,
then select "Statistics" in the main menu and read out the value of this last drawing.
Enter this value in the automatic function "Fill-Up" to use it for the next bathtub filling.
Note: In the event of a power cut whilst the automatic is running according to the
fill quantity, the water flow is stopped by the motor valve. After power is restored
the valve remains closed a prompt appears on the display and an alarm signal can be
heard until the prompt is acknowledged by tapping on "OK".
Automatics configuration
The behaviour of the timer at water stop and timer end can be adjusted here.
The motor valve of the DSX Touch can be opened again at any time via the item "Open
shut-off valve for water".