3.5
TECHNICAL SPECIFICATIONS
Description
Nominal heat input
Nominal heat output
Yield
CO measured at 13% oxygen
Flue outlet diameter
Minimum chimney effect
Combustion gases mass flow rate
Average flue gas temperature
Hourly wood consumption
Wood loading interval
External air intake (minimum useful cross-sectional area)
Minimum safety distance from flammable materials (side/rear/top/front)
Data measured in the laboratory in accordance with the product technical specifications.
The values in brackets (...) indicate the figures obtained in accordance with the EN 13240 standard.
The appliance heat output and consumption may vary depending on the type and degree of dryness of the wood used (an average value of 4,375
kWh/kg was considered).
3.6
DIMENSIONS AND CONNECTIONS
All the technical sheets for the dimensions and connections can be
viewed by scanning the following QR Code from your smartphone.
https://docs.klover.it/it/guide/help/cs-st90-tds-1
CS.ST90.IST-1_EN_Rev. 0.0_07-23
Unit of measure-
ment
kW
kW
%
%
mm
Pa
g/s
°C
kg/h
min
cm
2
mm
200 / 200 / 1500 / 800
EN
STAR 90
13,5
11,5
85,1
0,046
130
12
12
201
3,18
45
80
7