INSTALLATION
6.5
CONNECTION TO THE FUME EXHAUST
a
We recommend carefully reading the chapters
mum safety
clearances" and
The appliance is standard-configured with the fume exhaust on the
top (Su).
The fume exhaust can be modified using the rear fume outlet (Sb)
configured and present on the appliance.
Connection to the rear fume exhaust
l
To modify the configuration of the fume exhaust, it is
necessary to use the appropriate kit to be purchased
separately.
Proceed as follows:
- remove the hotplate and the upper fume exhaust (Su)
- loosen the screws and remove the cover of the fume deflector
- remove the plug on the rear fume exhaust (Sb)
x9
CS.ST90.IST-1_EN_Rev. 0.0_07-23
"Mini-
"Flue gas
channel".
Su
Sb
Fig. 11
Su
Fig. 12
- mount the outlet pipe of the rear fume exhaust (Sb) supplied with
the kit
- mount the cover of the fume deflector supplied with the kit, tighten
the screws removed previously
- mount the hotplate removed previously
- apply the cap supplied with the kit on the hotplate.
x9
x3
EN
Sb
Fig. 13
15