MANUAL PROCEDURE
In the MANUAL PROCEDURE, all the operations can be performed singly to the exception of
the recovery/recycling phase, which is automatically followed by used oil discharge.
The values for the quantity of gas recovered, quantity of oil recovered, vacuum time, quantity of
oil reintegrated, and quantity of gas charged into the system are automatically printed at the
end of each single operation.
From the MAIN MENU:
Select the MANUAL PROCEDURE
It's vertical rotating menu scrollable with the two arrow
RECOVERY
Connect the hoses to the A/C system with the quick-connect couplings, bearing in mind that
BLUE must be connected to the low-pressure side and RED to high pressure.
If the A/C system is equipped with a single quick-connect coupling for high or low pressure,
connect only the relative hose.
From MANUAL PROCEDURE, RECOVERY, the following screen will be displayed:
INSTRUCTIONS MANUAL
MAIN MENU
DD/MM/YY XX:XX PM
TANK PRESSURE
FLAG
6.32 BAR
ECK
TANK TEMPERATURE
17.9°C
REFRIGERANT AVAILABLE UV H
2735 g
, the following screen will be displayed:
MANUAL
DD/MM/YY XX:XX PM
Recovery
Vacuum
Oil-UV injection
Charge
A/C pressure check
AUTOMATIC / RECOVERY
DD/MM/YY XX:XX PM
Connect and open HP and LP couplings
To A/C system and press to continue
-39-
PAG
136ml
POE
110 ml
27ml
USED OIL
89 ml