FLUSHING KIT
Attention: before flushing, recover the refrigerant of the a/c system using a suitable R&R
device, then run at least 20 minutes vacuum.
When flushing a system we recommend disassembling the filter and the expansion valve, in
the case of a traditional system, or only the capillary valve in the case of a flooded system. Use
the inlet to the evaporator as washing inlet and the outlet of the condenser as flushing outlet.
From MANUAL, select FLUSHING KIT, the following screen will be displayed:
If needed, type the new value; then press
displayed:
Connect and open HP to A/C system and LP to flushing kit and press
The machine check leaks with vacuum