5.2
Equipment
Tab.123
Equipment for R32
Allowed for R32 gas only.
Do not reuse instruments from R22 or R407C gas.
Allowed for R32, R22 and R407C gas.
5.3
Possible combinations for multi-split systems
Tab.124 LSGT40-2M
1 unit
2.0 kW
2.5 kW
3.5 kW
5.0 kW
Tab.125 LSGT50-2M
1 unit
2.0 kW
2.5 kW
3.5 kW
5.0 kW
-
Tab.126 LSGT60-3M
1 unit
5.0 kW
-
-
-
-
-
-
-
7800852 - v02 - 10052022
The table below specifies which equipment can be used for multiple types
of refrigerant and which should only be used for R32.
Manifold
Charging hose
Refrigerant recovery equipment
Refrigerant cylinder
Refrigerant cylinder charging port
Gas leak detector
Vacuum pump without reverse-flow check valve
Vacuum pump with reverse-flow check valve
Pipe bender
Torque wrench
Pipe cutter
Welder and nitrogen cylinder
Refrigerant charging meter
Vacuum gauge
Refer to following tables to check which combination of indoor unit
capacity you can associate to the different outdoor units. Combinations not
listed in the tables cannot be used.
2 units
2.0+2.0 kW
2.0+2.5 kW
2.5+2.5 kW
-
2 units
2.0+2.0 kW
2.0+2.5 kW
2.0+3.5 kW
2.5+2.5 kW
2.5+3.5 kW
2 units
2.0+2.0 kW
2.0+2.5 kW
2.0+3.5 kW
2.0+5.0 kW
2.5+2.5 kW
2.5+3.5 kW
2.5+5.0 kW
3.5+3.5 kW
5 Installation
3 units
2.0+2.0+2.0 kW
2.0+2.0+2.5 kW
2.0+2.0+3.5 kW
2.0+2.5+2.5 kW
2.5+2.5+2.5 kW
-
-
-
en
165