Indoor unit installation height
1.8 m
2.2 m
5.7
Positioning the wall type unit
5.7.1
Installation location
Fig.187
>150
>150
2300 - 2600
5.7.2
Installing the mounting bracket
Fig.188
5.7.3
Refrigerant pipes connection
Fig.189
3
7800852 - v02 - 10052022
Refrigerant charge
Unit
LSGT70-3M
factory - maxi-
2
1.36 - 4.32
m
mum
factory - maxi-
2
0.91 - 2.89
m
mum
>150
MW6020010-02
MW-6020019-01
MW-6020016-01
LSGT100-4M
5.00 - 11.92
3.35 - 7.98
Select a suitable position in order to achieve a uniform air temperature
in the place of installation.
Consider the distribution of air from the indoor unit to the room.
Make sure that there are no sources of heat or steam nearby.
Consider noise reducing measures, like noise reducing wall anchors.
Make sure that there is space to install the condensate pipe with a slope
on the chosen location.
Respect the minimum distances required for the installation of the indoor
unit.
Caution
The wall must be solid and suitable to support 20 kg.
1. Position the mounting bracket on the wall.
2. Make sure that the mounting bracket is level.
3. Determine the position of the holes.
4. Drill holes in the wall for the mounting bracket.
5. Secure the mounting bracket to the wall.
6. Use a spirit level to make sure that the mounting bracket stays
horizontal and is perpendicular to the vertical direction.
If installed incorrectly, there may be water leakage from the indoor unit
when the air conditioner is operating in cooling mode.
1. Take out the refrigerant pipes connection.
2. Secure condensate pipe, refrigerant pipes and electric cables together
using plastic cable ties.
3. Wrap all pipes and cables with tape to prevent condensation.
en
5 Installation
LSGT125-5M
5.00 - 10.70
3.35 - 7.16
173