Fristam pumps are relatively maintenance free; however, in the event that a problem arises, the following
troubleshooting chart will help you with most of your pump-related problems. If a motor or drive problem
arises, please contact your local motor repair representative.
This troubleshooting chart has been prepared assuming the installed pump is suitable for the applica-
tion. If you have questions about your application please contact your local pump distributor to check
the system and re-evaluate the application or contact Fristam Pumps, Inc. at 1-800-841-5001 or 608-
831-5001.
p
RObLEM
No product flow,
pump not turning.
No product flow,
pump is turning.
Insufficient flow
Noisy operation.
Drive overload.
R7: 5/05
T
ROUbLESHOOTINg
C
AUSE
Power is not getting to the drive unit.
Coupler or belts are not connected,
slipping or broken.
Coupler or gear key sheared.
Pump rotation is incorrect.
Valve closed in suction line.
Suction line clogged or restricted.
Pump speed too slow.
Suction line does not remain flooded.
Excessive clearances in pump.
NIPA is too low.
Speed too low.
Cavitation.
Improper assembly.
Worn or damaged pump components.
Excessive forces from piping,
Excessive discharge pressure
Pump/drive misalignment
Viscosity of product higher than
expected.
Higher pressure than expected.
S
OLUTION
Have qualified person check
power source.
Install, adjust or repair as
necessary.
Replace.
Reverse rotation.
Open valve.
Clear suction line.
Increase speed.
Install foot or check valve.
Replace out of tolerance
components.
Improve suction conditions to
increase NIPA.
Adjust speed as required.
Improve suction conditions to
increase NIPA. Slow pump
down.
Check assembly.
Inspect and replace
components as necessary.
Support piping
independently.
Reduce discharge pressure.
Realign pump and drive.
Increase drive size.
Reduce pump speed, increase
piping size.