S
C
ISTEMA DE
Parameter Bytes
Command
or Key
1st
TUNER
–
Tuner Start
–
Dual Operation
–
[ RPT ]
–
[ A B ]
–
Set SUB
VFO-B
F1
Operating Freq.
BANDWIDTH
2ud & 3rd IF
X1
Filter Selection
MEM. Channel
–
Scan Skip
Step VFO-A
–
UP/DOWN
CTCSS
Encoder
E
Tone Frequency
Select
Read Meter &
–
Panel Controls
Repeater
X1
Offset
página 96
A
ONTROL
SISTIDO POR
Opcode Command Chart (3)
Opcode
2rd
3rd
4th
5th
–
–
T
81H
–
–
–
82H
D
–
–
83H
–
–
R
84H
–
–
–
85H
F2
F3
F4
8AH
–
–
X4
8CH
–
S
X
8DH
–
–
T
8EH
E
E
E
90H
–
–
–
F7H
X2
X3
X4
F9H
C
OMPUTADORA
Parameter Description
Switch Antenna Tuner ON ( T = 01H ) or OFF ( T = 00H )
Start Antenna Tuning
Switch Dual Receive ON ( D = 01H ) or OFF ( D = 00H )
Switch Simplex Operation ( R = 00H ), Minus Shift ( R = 01H ),
or Plus Shift ( R = 02H ) for Repeater Operation
Copy Data Display in VFO-A or VFO-B.
Enter new operating frequency in F1 ~ F4, in BCD format:
see text for example.
Select filter bandwidth for selected IF ( see below ) :
8.2 MHz
455 kHz
THRU: X4 = 04
6.0 kHz: X4 = 84
2.4 kHz: X4 = 00 2.4 kHz: X4 = 80
2.0 kHz: X4 = 01 2.0 kHz: X4 = 81
500 Hz: X4 = 02 500 Hz: X4 = 82
500 Hz: X4 = 03 500 Hz: X4 = 83
Tag memory channels 1 thruogh 99 ( X = 01H ~ 6CH ) , to be
skipped ( S = 01H ) or included ( S = 00H ) while scanning.
Step frequency of VFO-A UP ( T = 00H ) or DOWN ( T = 01H )
Select one of 33 CTCSS subaudible tones
where E = 00H ~ 20H
E = 00H 67.0 Hz E = 0BH 118.8 Hz E = 16H 173.8 Hz
E = 01H 71.9 Hz E = 0CH 123.0 Hz E = 17H 179.9 Hz
E = 02H 77.0 Hz E = 0DH 127.3 Hz E = 18H 186.2 Hz
E = 03H 82.5 Hz E = 0EH 131.8 Hz E = 19H 192.8 Hz
E = 04H 88.5 Hz E = 0FH 136.5 Hz E = 1AH 203.5 Hz
E = 05H 94.8 Hz E = 10H 141.3 Hz E = 1BH 210.7 Hz
E = 06H 100.0 Hz E = 11H 146.2 Hz E = 1CH 218.1 Hz
E = 07H 103.5 Hz E = 12H 151.4 Hz E = 1DH 225.7 Hz
E = 08H 107.2 Hz E = 13H 156.7 Hz E = 1EH 233.6 Hz
E = 09H 110.9 Hz E = 14H 162.2 Hz E = 1FH 241.8 Hz
E = 0AH 114.8 Hz E = 15H 167.9 Hz E = 20H 250.3 Hz
Instruct radio to return digitized indications of various meter
level readings and front panel control settings (4 repeated
bytes, and F7H) selected by:
M = 00H Main S-Meter
M = 01H Sub S-Meter
M = 80H PO Meter
M = 81H ALC Meter
M = 83H IC Meter
M = 84H VCC Meter
M = 85H SWR Meter
M = 86H MIC Meter
Set offset for RPT shift, valid values are
0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.
X1 is 10's & 100's of Hz
X3 is must be 00H, 01H, or 02H
CAT
VFO
Both: X1 = 00
VFO-A: X1 = 01
VFO-B: X1 = 02
M = 87H TUN Meter
M = F0H Shuttle Jog Dial
M = F1H CW Pitch Setting
M = F2H Remote Control A/D Level
M = F3H SHIFT Setting
M = F4H WIDTH Setting
M = F5H EDSP Contour Selection
M = F6H EDSP NR Selection
X2 is 1's & 10's of kHz
X4 is must be 00H
Manual de Instrucciones