8.0 Setup screens
Press once on the Setup shortcut key to enter the setup screens.
Time + Grow day
Set current time here. The time setting is in 24 hour format.
Grow day should be set to 1 at the beginning of the flock. This value is incremented
every day at Reset Time (see reset time below).
Press again on the Forward arrow
arrow
to go back to the previous screen
Reset time
The time of day in 24-Hours format in which the daily consumption is saved for history
and grow day is incremented.
Provision fill weight
Enter here the weight in Kilograms that is to be filled into the daybin.
Auger Alarm Time
The time (in MM:SS format) it takes the system, when the Fill motor or one of the
Augers is running, to detect that the bin weight is stable, meaning that the motor is not
running, and to set the FILL or FEED alarms (see Alarms on page 24). If this value is set
to 99:99 then these alarms are disabled. The default value is 1:00 (one minute).
Note: The Auger Alarm Time must be set to 99:99 if any of the 3 auger contactors is not
connected to the AUGER INPUT as described in paragraph 6 on page 7.
Roxell Daybin Controller – RDC
Set Time:
10:10
Grow Day:
key to go to the next Setup screen. Use the Back
Reset Time
08:00 HH:MM
HH:MM
Bin Fill Weight
100 Kg
Auger Alarm Time
01:00 MM:SS
Page 13 of 193