Diagnostic screens

Diagnostics
In the diagnostic screen press on the Program key
back arrows
Start Weight is the Daybin weight in Kilograms before the beginning of the current batch.
End Weight is the Daybin weight at the end of the last batch given.
Pulse Count is a display of how many feed pulses has been given for the current batch.
Kg to Give is the amount of feed for the current batch that has yet to be given.
The Last Pulse Kg (Lb) displays exactly how much feed was given in the last pulse.
Calc Error is the exact amount of feed given in Kg (Lb) in excess of the batch quantity.
Auger 1 Over Flow is the last batch overshoot in Kg(Lb) for females feeding.
Auger 2 Over Flow is the last batch overshoot in Kg(Lb) for males feeding.
Roxell Daybin Controller – RDC
Diagnostics
to scroll through the 7 diagnostic screens.
Diagnostic 1
Start Weight: 480
End Weight: 380
Diagnostic 2
Pulse Count:
Kg to Give:
Diagnostic 3
Last Pulse Kg:
Calc Error:
Diagnostic 4
Auger 1 OvSH
Auger 2 OvSH
Page 19 of 193
once then use the Forward and
5
9.8
0.8
0.5
5.0
4.7