Operating Instructions SATA spray master RP
EN
[1-13] Nozzle set
[1-14] Pressurised cup
7. Technical Data
Description
Recommended spray gun inlet
pressure
Max. spray gun inlet pressure
Max. air working pressure
Max. cup pressure
Cup pressure variable from
Recommended spraying distance
Air consumption
Max. temperature of the material
Weight (without material)
aluminium flow cup 750 ml
8. Operation
Warning!
Risk of injury from bursting compressed air hose
If an unsuitable compressed air hose is use, it can be damaged by too
much pressure and explode.
→ Only use solvent-resistant, antistatic and technically flawless hose
for compressed air with permanent pressure resistance of min. 10 bar,
bleeder resistance of < 1 MOhm and min. inner diameter of 9 mm
(# 9902).
Attention!
Damage from dirty compressed air
Using soiled compressed air can cause malfunctions
.
→ Use clean compressed air. For example with SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
Before using the spray gun, heed / check the following points to warrant
safe working:
124
[1-15] Screw-on lid
150 - 230 Nl/min at 1 - 2 bar
RP
1.0 bar - 2.0 bar
10.0 bar
3.0 bar
1.7 bar
0 - 1.7 bar
17 cm - 21 cm
50 °C
1300 g