Maintenance And Repairs - SATA spray master RP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 137
Operating Instructions SATA spray master RP
Adjust spray fan pattern
Fully variable adjustment of the spray fan pattern is possible using the
round/flat fan control [1-7] to achieve a round fan.
■ Adjust the spray fan pattern by regulating the round and flat fan control
[1-7].
■ Turn to the right – round fan
■ Turn to the left – flat fan
Start spraying process
■ Observe correct spray distance (see chapter 7).
■ Pull trigger guard right back [1-2] and hold spray gun at 90° to the
surface being sprayed.
■ Ensure there is sufficient spraying air feed and material supply.
■ Pull trigger guard back and start spraying process. Adjust material flow
and spray fan pattern if necessary.
End the spraying process
■ Bring the trigger guard [1-12] to the starting position.
■ At the end of the spraying process, interrupt the spraying air and empty
the gravity flow cup [1-14]. Comply with the instructions for care and
storage (see chapter 10).

9. Maintenance and repairs

Warning!
Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Warning!
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
The following chapter describes the procedures involved for maintaining
and repairing the
EN
127

Publicidad

Tabla de contenido
loading

Tabla de contenido