Enabling Of Management For Opening With Automatic Re-Closure Exclusion; Setting Reverse Time After Activation Of Sensing Edge Or Obstacle Detection; (Crush Prevention); Setting Motor Torque - Roger Technology B70/1DCHP Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 148

Enabling of management for opening with automatic re-closure exclusion.

If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter. For
example: if you set
a PP or PED command.
NOTE: The command has open-stop-close or close-stop-open sequence activation function.
Disabilitata.
Un comando AP (apertura) attiva la manovra di apertura. Con cancello completamente aperto la richiusura auto-
matica è esclusa. Un successivo comando AP (apre) attiva la manovra di chiusura.
Un comando PP (passo-passo) attiva la manovra di apertura. Con cancello completamente aperto la richiusura
automatica è esclusa. Un successivo comando PP (passo-passo) attiva la manovra di chiusura.
Un comando PED (apertura parziale) attiva la manovra di apertura parziale. La richiusura automatica è esclusa. Un
successivo comando PED (apertura parziale) attiva la manovra di chiusura.

Setting reverse time after activation of sensing edge or obstacle detection

(crush prevention).

This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system. The gate
comes to a stop after reversal dues to activation of the sensing edge or obstacle detection system at the end of
manoeuvre deceleration speed. As a result, the effective reversal manoeuvre time is slightly longer than the set
time.
From 0 to 60 s.

Setting motor torque

Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
(strong winds or very cold temperatures).
01= -35%; 02= -25%; 03= -16%; 04= -8% (reduced motor torque = increased sensitivity).
05= default motor torque setting.
06= +8%; 07= +16%; 08= +25%; 09= +35% (increased motor torque = reduced sensitivity).

Setting obstacle impact force sensitivity

If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force
exerted on obstacles is too high, reduce the value of parameter
Low motor torque:
01 = minimum obstacle impact force ... 10 = maximum obstacle impact force
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
11 = minimum obstacle impact force ... 16 = maximum obstacle impact force.
70% of maximum motor torque, 1 s of reaction time. Sensing edge is compulsory.
80% of maximum motor torque, 2 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 3 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 5 s of reaction time. Sensing edge is compulsory.
Setting start acceleration during opening and closing
See chapters 14 and 15
01= the gate accelerates rapidly at start of manoeuvre ... 05= the gate accelerates slowly and progressively at
start of manoeuvre.

Enabling maximum torque boost at start of manoeuvre

If this parameter is enabled, each time the motor starts a manoeuvre, maximum torque is produced for a maximum
of 5 seconds, or for the time necessary for the gate to open by approximately 65 cm.
N.B: in the case of High Speed and Reversible motors, a motor boost mode is implemented for 2 seconds after
each gate start, regardless of the setting of parameter
Disabled.
Enabled at start of opening manoeuvre only (including position recovery). The motor starting current function
is only enabled for closing manoeuvres if the gate position is known and the gate is over to 2 metres from the
completely closed position.
Enabled for all starts (including position recovery).
70
, automatic re-closure is excluded following an AP command, but it is activated following
ONLY for particularly lightweight installations not exposed to severe weather conditions
.
.

Publicidad

Tabla de contenido
loading

Tabla de contenido