TABELLA PARAMETRI MENÙ FUNZIONI
PARAMETRO
Funzione
PARAMETER
Function
PAR
Función
Rapporto TV 1
P.41
VT1 Ratio
Relación VT1
Rapporto TV 2
P.42
VT2 ratio
Relación VT2
P.43
Funzione ingresso programmabile mors. 18-19
Programmable input function terminals 18-19
Función de entrada programable terminales 18-19
P.44
Secondo set-point cosϕ
Second cosϕ setpoint
Segundo Setpoint cosϕ
P.45
Soglia minima tensione
Minimum voltage threshold
Umbral mínimo de tensión
Soglia massima tensione
P.46
Maximum voltage threshold
Umbral máximo de tensión
Soglia step difettoso
P.47
Step failure threshold
Umbral paso defectuoso
Misura eventi armonici
P.48
Measurement of harmonic event
Medida de eventos armónicos
P.49
Soglia eventi armonici
Harmonic event threshold
Umbral eventos armónicos
P.50
Ritardo eventi armonici
Harmonic event delay
Retardo eventos armónicos
P.51
Protocollo RS232
RS232 Protocol
Protocolo RS232
Indirizzo seriale RS232
P.52
RS232 serial address
Dirección RS232
Velocità RS232
P.53
RS232 speed
Velocidad RS232
Parità RS232
P.54
RS232 parity
Paridad RS232
P.55
Lunghezza word RS232
RS232 word length
Longitud de palabra RS232
P.56
Protocollo RS485
RS485 Protocol
Protocolo RS485
P.57
Indirizzo seriale RS485
RS485 serial address
Dirección puerto RS485
Velocità RS485
P.58
RS485 speed
Velocidad RS485
Parità RS485
P.59
RS485 parity
Paridad RS485
Lunghezza word RS485
P.60
RS485 word length
Longitud de palabra RS485
14
TABLE OF FUNCTIONS MENU PARAMETERS
Range
Range
Rango
1.0...250.0
1.0...250.0
OFF
Disab. -
Disab. -
OFF
Desh. -
OFF
OFF
- 0.80Ind .. 0.80Cap
OFF
- 80...750V
OFF
- 80...750V
OFF
- 25...100%
Sovracc. Condensatori -
Ccur
Ccur
Capicitor current overload -
Sobrecarga condensadores -
Ccur
1...250%
1...240s
RTU
Modbus RTU -
Modbus RTU -
RTU
RTU
Modbus RTU -
1... 247
-
OFF
1200
nessuna -
OFF
OFF
none -
none -
OFF
8bit
7bit
RTU
Modbus RTU -
Modbus RTU -
RTU
RTU
Modbus RTU -
1... 247
-
OFF
1200
nessuna -
OFF
OFF
none -
none -
OFF
8bit
7bit
TABLA DE PARAMETROS MENÙ FUNCIONES
NTC
Sens. temp. ntc -
2Co
Secondo set-point cosϕ -
NTC temp. sensor -
2nd cosϕ setpoint -
NTC
2Co
Sens. de temp. NTC -
2° setpoint cosϕ -
NTC
2Co
THD tensione -
UTHD
ITHD
UTHD
Voltage THD -
THD tensión -
UTHD
ASC
Modbus ASCII -
AAns
Modbus ASCII + risposta modem
Modbus ASCII -
Modbus ASCII + modem answer
ASC
AAns
ASC
Modbus ASCII -
AAns
Modbus ASCII + respuesta modem
baud -
baud -
baud -
2400
4800
9600
dipari -
pari
Odd
Eve
Odd
odd -
Eve
even
odd -
even
Odd
Eve
ASC
Modbus ASCII -
AAns
Modbus ASCII + risposta modem
Modbus ASCII -
Modbus ASCII + modem answer
ASC
AAns
ASC
Modbus ASCII -
AAns
Modbus ASCII + respuesta modem
baud -
baud -
baud -
2400
4800
9600
dipari -
pari
Odd
Eve
Odd
odd -
Eve
even
odd -
even
Odd
Eve
NoA
Allarme NA -
NcA
Allarme NC
NO alarm -
NC alarm
NoA
NcA
Alarma NA -
Alarma NC
NoA
NcA
THD corrente
ITHD
Current THD
THD corriente
ITHD
baud -
baud -
baud
19200
38400
baud -
baud -
baud
19200
38400
Default
1.0
1.0
OFF
OFF
OFF
OFF
OFF
Ccur
120
5
RTU
1
9600
OFF
8bit
RTU
1
9600
OFF
8bit