RECEIVER
In OPERATION mode the 7 LED's must be lit as has been previously described in section 4.3 Starting. If this is
so, press the transmitter manoeuvre buttons and observe the response of the output relays. If the response is
normal, the problem is not related to the remote control equipment and the installation must be checked. If any
of the relays is not activated, the problem is associated with the remote control equipment. If this happens,
observe the appearance of the LED's:
LED
POWER
HARDOK
SIGNAL
DATA
ID
ORDER
RELAY
There are also two LEDs in the receiver (only available in LR72 electronic card) which informa about the status
of the CAN-BUS. If the CAN connection is not working, check the status of the LEDs:
LED
CAN_RUN
CAN_ERR
If the problem is associated with the equipment, please send both the transmitter and the receiver
to the your Technical Assistance Service Agent, together with a description of the problem and the
status of the LED's.
If the transmitter becomes so damaged that a spare has to be arranged, it can be quickly
substituted by following the instructions in ANNEX A.
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
LIT
Power Supply OK
Slow: fault in the board
Board OK
Fast: error in EEPROM
RF signal OK
RF signal detection in
SCANNING mode
--
Is receiving the correct data
from a TM70
--
ID Code OK
Any digital
--
manoeuvre ON
STOP relays ON
--
LIT
Operating status
Fatal Error
FLASHING
--
FLASHING
Pre-operating status
Communication error
OFF
Power Supply not OK
Fault in the board
The receiver is not receiving
RF signals
Signal received is not
correct
ID not recognised
No digital manoeuvre ON
STOP relays OFF
OFF
CAN communication non
active
CAN controller OK
13