ANNEX A - PROGRAMMING A SPARE TRANSMITTER.

In case of damage to the transmitter, it is quickly possible to restore service, if a spare
transmitter is available. To achieve this we have to install into the spare transmitter the
exact parameters of that to be replaced.
These parameters are stored in an EEPROM memory module,
accessible from the exterior of the transmitter. Switch off the damaged transmitter and
extract the EP70 module by unloosening the two screws, as shown, and then
incorporate this module into the spare transmitter.
In cases where the damage to the transmitter prevents
removal of the EP70 module, the spare transmitter can be
programmed with the memory module EP70 found inside
the receiver.
To achieve this, proceed as follows:
1.
Being the spare transmitter off, remove its
empty EP70 module as described above, and insert the
EP70 module from the receiver.
2.
Introduce a charged battery, turn on the
ON/OFF key, push and extract the STOP button. The LED
will pulse green for around 15 seconds.
3.
To copy its contents into the internal memory
of the transmitter press pushbutton 6 followed by START,
keeping both buttons pressed together while LED blinks
red. Once the LED start to blink orange, release the
pushbuttons and LED will lit green. In the LCD display
models the words "Reading..." and "Reading ok Change
EEP" will be indicated. In case the LED remains in red
colour, (or the LCD displays "Reading nok"), repeat the
process.
4.
When the copying process has completed,
extract the EP70 and replace it into the receiver. Insert the
empty EP70 into the spare transmitter and again press
pushbutton 6. The LED will flash orange, which indicates
that the empty EP70 is being written with the stored
parameters In the LCD display models the words "Writing..."
and "Writing ok" will be indicated. In case the LED remains in red colour, (or the LCD displays "Writing nok"),
repeat the process.
5.
Afterwards press the STOP. This completes the programming processes.
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
EP70, easily
15

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para IKUSI TM70 Serie

Este manual también es adecuado para:

T70/1T70/2

Tabla de contenido