Display error messages V 2.4:
Error message
Cause
"Tilt switch "
Inclinometer detected due to an incorrect position of the
transmitter
"Out of Range"
Transmitter out of range
"Wrong Crane "
Crane selector is in wrong position after a crane has been
selected previously
"Error EEP"
Error when trying to access the content of the EEPROM or the
internal memory. The content of the EEPROM cannot be copied
into the internal memory
"Error Wrong
EEPROM data corrupted
EEP"
"Error Copy
When duplicating EEPPROM modules a copy failure occured
FLASH"
during the new EEPROM updating process
"Error Open File"
Internal memory access failure
"Error File Write"
Error when writing EEPROM data into the flash memory or
timeout error occured when trying to access to the memory
"Error File Close"
Error when trying to close the internal memory access
"Error Open
The radio cannot be opened
Radio"
"Error Write
Data cannot be written in the radio
Radio"
"Error OP &
When releasing the STOP pushbutton the signals and the masks
Masc"
do not match indicating that some masked order is still activated.
"Error Bad data
EEPROM data corrupted
EEP"
"Error LAL not
Error when trying to open the range limiter
open"
"Error Read LAL
Range limiter data cannot be read
err"
TM70Bi V4.1 (03/12)
1121174.pdf