1� About this document
– Please read carefully and keep in a safe place.
– Under copyright.
Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
!
Disconnect the power supply before attempting any work on the sensor�
• This product must only be installed by a qualified electrician in accordance with
national wiring regulations as defined in VDE 08 29 (DIN EN 5000 90).
• Installed improperly, low-voltage products can cause extremely serious personal
injury or damage to property.
• This product must never be connected to a 230 V AC power supply as it is intend-
ed for connection to an extra-low voltage power supply.
• Only use genuine replacement parts.
• Repairs may only be made by specialist workshops.
3� IS 3360, IS 3360 MX, IS 345, IS 345 MX, IS 3180 KNX
Proper use
– IS 3360 MX KNX and IS 345 MX KNX are suitable for indoor ceiling mounting.
– IS 3360 KNX and IS 345 KNX are suitable for indoor- and outdoor ceiling mounting.
– IS 3180 KNX is suitable for wall mounting indoors and outdoors.
– The concealed versions are only suitable for installing indoors.
The infrared sensor can be used for switching light ON and OFF automatically. The
unit is not suitable for burglar alarm systems as it is not tamperproof in the manner
prescribed for such systems. The motion detector is equipped with pyro sensors that
detect the invisible heat emitted from moving objects (people, animals etc.). The heat
detected in this way is converted electronically into a signal that switches a connected
load ON (e.g. a light). The built-in red LED also lights up. The sensor does not detect
22
heat radiated from behind obstacles, such as walls or panes of glass. Heat radiation
of this type will therefore not activate a light.
Optionally, all function settings can be made via the RC6, RC7 remote controls as
well as the Smart Remote. (  "7� Accessories")
Package contents for surface-mounted installation (Fig� 3�1)
Package contents for concealed installation (Fig� 3�2)
Product components (Fig� 3�3)
Status LED
Programming button
Load module, power supply lead, surface-mounted
Load module, power supply lead, concealed
Designer trim, round or square
Sensor module
Shroud
Product dimensions
Surface-mounted / concealed (Fig� 3�4)
IS 3360 KNX, IS 3360 MX KNX, IS 345 KNX
Surface-mounted / concealed (Fig� 3�5)
IS 345 MX KNX
Surface-mounted / wall-mounted (Fig� 3�6)
IS 3180 KNX
4� Installation
Wiring diagram (Fig� 4�1)
An optional corner wall mount is available for mounting the IS 3180 KNX (Prod. no.
035174 white).
– Surface-mounted installation
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP54) double seal cable gland.
For mounting on the wall, a condensation water drainage hole (Ø 5 mm drill bit) is
marked next to the rubber seal. This must be opened if necessary. (Fig� 5�3)