INITIAL SYSTEM SETUP
The StreamMaster II allows many configuration options during setup .
The following functions can be configured in the setup mode:
• Right, Left, Up and Down Soft Limit Positions
• Monitor Orientation (sideways or inverted mounting)
• Position Sensor "Zero"
• Restore Factory Defaults
• Obstacle Avoidance
• Electric Riser Disable/Enable
• Stow and Deploy Positions
To enter the setup mode for the above functions, follow these steps:
1 . Turn power off to StreamMaster II
2 . Press and HOLD the Stream switch (can be done on the Joystick or the Toggle Switch Box)
3 . Turn power on to StreamMaster II while continuing to hold the Stream switch
4 . Wait 3-4 seconds and release the Stream switch
The StreamMaster II should now be in setup mode . When in setup mode, the LED on the operator station will be slowly blinking (a
short blink followed by a long pause) . If it is not slowly blinking, turn the power off and repeat steps 1-4 .
All setup functions except the Stow and Deploy Positions can be scrolled through by pressing the Stream switch . Each time the
Stream switch is pressed, another function is active for configuration . If a function is configured and saved using the Fog switch, the
next function will be automatically selected . For example, the first time the Stream switch is pressed, the Right Soft Limit Position
(LED Code 1-1) is ready for programming . If it is pressed again, the Left Soft Limit Position (LED Code 1-2) is ready for programming .
If the Left Soft Limit Position is set and the Fog switch is pressed, the Up Soft Limit Position (LED Code 1-3) will be automatically
selected without having to press Stream again . Alternatively, activating the Stream command will abort this function without storing
the position and the next function will be selected . Entering the Stow and Deploy Positions programming modes can only be accom-
plished by activating the Stow or Deploy switch while at the start of the setup menu (LED Code 1 Slow blink) . (See the sections for
Stow Position and Deploy Position for more detail) .
To aid in determining which setup menu the StreamMaster II is in, the LED on the operator station has been programmed to blink a
different code for each function . The table below lists the LED codes for each function . The codes have two parts . The LED code will
start with either one or two short blinks, a short pause, another series of short blinks, and then a long pause . The first number in the
LED code is the one or two blinks and the second number is the second series of blinks before the long pause . There is also an LED
on the front of the 6052 StreamMaster II Controller that will display the status codes . The controller is mounted at the base of the
monitor .
Page 11