Elevation Stops
The StreamMaster II™ has 120° of travel above horizontal and 45º below horizontal, which is limited by the permanent stop . This stop
should not be removed . Stops can be inserted to limit travel above and below horizontal according to figure 4 . Factory default stops
are set at 45° above horizontal and 45° below horizontal . The stops and plugs have a 5/8" hex head . If a hole does not have a stop, it
should have a plug .
Operating the monitor without the permanent travel limit stops in place could cause damage to the monitor
and could potentially injure the operator .
Figure 4 – Elevation Stops
Nozzle Installation
The nozzle should be threaded onto the outlet of the monitor . Position the pattern actuator in a position that does not stretch the
power cord, and then tighten the swivel . Verify that the actuator orientation does not interfere with the monitor .
Ensure the thread on the nozzle swivel matches the thread on the monitor outlet . Do not over-tighten the
nozzle onto the unit .
Use a nozzle of the same material as the monitor to eliminate the effects of galvanic corrosion .
120°
PT A
(PERMANENT)
90°
PT Y
45°
PT Z
PT Y
(FACTORY
SET)
PT Z
-15°
-45°
PT B
PT A
(PERMANENT)
MONITOR SHOWN WITH DECRATIVE COVER REMOVED.
Page 7
PT A
PT B