Any of the following functions may be configured by stopping at that function and performing the operation . See the appropriate
section for detailed information on configuration of each function .
Setup Menu Function
Setup Mode Start
Right Soft Limit Position
Left Soft Limit Position
Up Soft Limit Position
Down Soft Limit Position
Monitor Orientation
Position Sensor "Zero"
Restore Factory Defaults
Obstacle Avoidance Disable
Obstacle Avoidance Manual Operation
Obstacle Avoidance Auto Operation
Obstacle Avoidance Learn
Electric Riser Disable
Electric Riser Enable
Stow Position
Deploy Position
Setup Mode Table for LED Codes
While any and all of these configurations are optional, if a monitor orientation is mounted sideways or inverted, the monitor
orientation will need to be configured for proper operation . If at any point it is determined that an undesirable mode is active, it is
possible to abort the mode by removing power to the StreamMaster II prior to activating the Fog input . If it is determined that an
undesired function may have been saved, it may be desirable to use the "Restore Factory Defaults" function (LED Code 1-9) . When all
desired changes have been made, cycling power will return the monitor to normal operation and the changes that were made will be
in effect . The changes can also be saved by pressing the Fog switch when in setup start mode (one single blink) .
The position sensors are "zeroed" at the factory . The default zero position is facing straight ahead with the nozzle level (0º eleva-
tion) . If the monitor is physically mounted such that this is not the zero position for your installation, you will need to re-zero the
monitor before it can be used with a 6036 Direction Indicator .
Soft limits can be set to shorten the rotational and elevation range . NOTE: Use of this function will clear all stored obstacle avoid-
ance option profile data and require the obstacle avoidance to be re-programmed. Factory defaults are set to a soft limit location
beyond the hard stops so that the monitor will have full range of motion between hard stops until the soft limits are set .
LED Code
1 slow blink
1-1
1-2
1-3
1-4
1-7
1-8
1-9
2-1
2-2
2-3
2-4
3-1
3-2
1-5
1-6
Page 12