Configuracion De Las Funciones (Tab. 2); Regulacion De La Potencia - motormatic CT-200 Manual De Instrucciones

Tabla de contenido

Publicidad

GB
MOR.
MOR.
DEVICE
n.
n.
28
25 o 31 N.O. pushbutton
29
25 o 31 N.C. contact
30
25 o 31 N.O. pushbutton
Receiver
32
antenna Rx*
Receiver
33
antenna Rx*
34
35
Auxiliary
max 24V
Input
Output
* ANTENNA: pay attention if a plug-in radio card is used, since the connector for antenna connection in
certain models is on the actual card.
** If a command is sent with the photocell obscured and gate closed, the control unit does not carry out an
opening movement until the photocell is freed. The command is stored in the T100 for 10 seconds and
the flashing light comes on as a warning.
PROGRAMMING THE WORKING AND PAUSE TIMES
The control unit memorises the working and pause times during programming.
During the learning phase, the key P/P (det. 18 of fig 1) is activated several times, alternatively the control
P/P (terminal 30, fig. 2) or the remote control (if memorised) may be used.
Important checks prior to programming.
- With systems using an electric lock, it should be mounted on the gate leaf driven by motor M1.
- Power the control unit and check correct operation of the control inputs through the relative LEDs (the
LEDs should be on for the NC contacts and off for the NO contacts).
- If the photocell transmitters are powered with the output for the foto-test (term. 14 and 15) check correct
operation by short-circuiting the two "Test" pins (part 13 of fig.1).
- Free the gate area of movement.
- Select one of the types of automation described below to carry out self-learning of the times.
I
V
FUNCTION
NOTES
max
With 2 motors, opening is carried out
Pedestrian gate
by just motor M1. With 1 motor, ope-
ning is for just 6 seconds.
Stop all functions. Connect this input if
Stop
not used to the common terminal.
See functions dip switches No. 1 and
Step-by-step
No. 2
For the incorporated receiver, use an anten-
Control unit
na tuned to 433 MHz. Should a receiver be
connected to the pre-installed connector,
see the antenna characteristics required by
Braid
the manufacturer.
Only available if a two-channel radio
II° Receiver
500mA
card is inserted in the pre-installed con-
channel
nector.
25
E

CONFIGURACION DE LAS FUNCIONES (tab. 2)

La central se suministra con una configuración estándar, como se observa en el n° 11 de la fig. 1.
Se pueden escoger opciones al funcionamiento estándar configurando de manera diferente el dip-switch
funciones (n° 11 de la fig. 1).
Téngase en cuenta que, para que la central pueda memorizar una variación de las configuraciones,
es necesario cortar y restablecer el suministro de corriente (RESET).

REGULACION DE LA POTENCIA

El compensador PW (n° 17 de la fig. 1) regula la potencia del motor (girándolo en el sentido de las agujas
del reloj, la potencia aumenta).
La regulación PW no se toma en consideración cada vez que se empieza una maniobra, situación en la
que se da plena potencia durante algunos segundos (toma de fuerza), y durante la fase de deceleración.
NOTAS:
Si la potencia se regula demasiado baja, puede suceder que intervenga la tarjeta MAS200 (si ha sido
introducida).
SOFT START
La función Soft Start hace ejecutar el inicio del movimiento de manera gradual, evitando sacudidas del auto-
matismo. Esta función se puede excluir puenteando Jp1 (n° 16 de la fig. 1).
¡ATENCION!
Excluyendo la función Soft Start, automáticamente se excluye, también, la regulación de la poten-
cia del motor. En este caso, los motores deben estar dotados de una regulación de fuerza propia
(ej.: embrague mecánico).