Cebora RDI210 Manual De Instrucciones Para Interfaz página 21

Para installacciones mig y tig robot

Publicidad

Idiomas disponibles

Idiomas disponibles

3.9.1
Error code for K-Bus diagnosis.
Error
Argument
Code.
0
-
0
1
1
2
2
-
3
0
0
4
n
5
n
0
1
6
2
7
0
0
9
1
10
n
14
n
15
n
16
n
3.300.987-H
Description
EMC problem
Eeprom checksum error
Code buffer overflow.
Unknown data type.
Reserved.
K-Bus command error
K-Bus data error, break
behind the Controller.
Break
behind
Bus
Terminal n
K-Bus error in register
communication with Bus
Terminal n.
Error at initialization.
Internal data error.
Rotary switches changed
after a software reset.
Cycle time was exceeded.
Checksum error in flash
program.
Incorrect or fault library
implemented.
Bus Terminal n is not
consistent
with
the
configuration that existed
when the boot project was
created.
Nth Bus Terminal has the
wrong format.
Number of Bus Terminal
is no longer correct.
Length of the K-Bus data
is no longer correct.
Solution
Check power supply for over voltage or under
voltage peaks. Implement EMC measures.
If a K-Bus error is present, it can be localized by a
restart of the controller (by switching it off and
then on again).
Set factory setting with KS configuration
software.
Insert fewer Bus Terminals. The programmed
configuration has too many entries in the table.
Software update required for the Controller.
-
No Bus Terminal inserted.
One of the Bus Terminal is defective; Halve the
number of Bus Terminals attached and check
whether the error is still present with the
remaining Bus Terminals.
Repeat until defective Bus Terminals is located.
Check whether the n+1 Bus Terminals is correctly
connected; replace if necessary.
Check the Bus End Terminal KL9010 is
connected.
Exchange the nth Bus Terminal.
Replace Controller.
Perform a hardware reset on the Controller (switch
off and on again).
Perform a hardware reset on the Controller (switch
off and on again).
Warning: the set cycle time was exceeded.
This indication (flashing leds) can only be cleared
by booting the Controller again.
Remedy: increase the cycle time.
Transmit program to the Controller again.
Remove the fault library.
Check the nth Bus Terminal.
The boot project must be deleted if the insertion of
an nth Bus Terminal is intentional.
Start the Controller again, and if the error occurs
again then exchange the Bus Terminal.
Start the Controller again. If the error occurs
again, restore the manufacturers setting using the
KS2000 configuration software.
Start the Controller again. If the error occurs
again, restore the manufacturers setting using the
KS2000 configuration software.
GB
21