Spare Parts; List Of Spare Parts - Tractel Group altotir 200 Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

14.3 Spare parts

14.3.1 List of spare parts

The following replacement accessories can
be procured and mounted:
o Equipped wire rope (to be mounted by a
technician only).
o Power connector (Fig. 1, item 20).
The power connector must only be installed
by an electrician.
o Adjustable limit stop lever kit (Fig. 1, item 9)
(to be mounted by a technician only).
o Control unit (Fig. 1, item 15).
The control unit must only be installed by an
GB
electrician.
DANGER: Before any intervention
on a replacement accessory, wire rope
included, the operator must first remove the
load and shut down the winch.
IMPORTANT: After installing a repla -
cement accessory, switch on the winch and
perform a functional test before using the
winch as indicated in the table in section
14.1.
14.3.2 Procedure for disassembly and
installation of wire rope
The wire rope must only be replaced by a
technician.
The wedge socket with wire rope is shown in
figure 13.
Composition:
1) Taper plate
2) Plate bearing piece
3) Wedge socket
4) Warping drum
5) Wire rope loop
6) Wire rope end
7) Drum flange hole
8) Wire rope
9) Plate tip
10) Limit stop lever opening
X Length of section of wire rope coming
out of wedge socket.
The change of wire rope is shown in figure
14.
Tools:
• 1 flat head screwdriver
Procedure for disassembly of wire rope
IMPORTANT: When replacing the
wire rope, appropriate wire rope handling
safety gloves should be worn.
• Fully unwind the wire rope by acting on
the control unit (Fig. 1, item 15).
• Set the winch so that it bears on its
carrying handle (Fig. 1, item 11).
During this operation, be careful to protect
the clamp fastening studs (Fig. 1, item 13) to
avoid any damage to the threads.
• Place the wedge socket (Fig. 13) in
position by momentarily pressing the
control button on the control unit (Fig. 1,
item 13).
• Shut down the winch and disconnect the
electrical power supply.
• Remove the wire rope as shown in
figure 14:
a) Insert the tip of the screwdriver
between the wire rope loop (Fig. 13,
item 5) and the taper plate bearing
piece (Fig. 13, item 2).
b) Turn the screwdriver to apply pressure
in order to release the wire rope.
c) Remove the end of the wire rope
(Fig. 13, item 6) from the wedge socket
(Fig. 13, item 3) using the screwdriver.
d) Remove the taper plate.
e) Pull the wire rope, sliding it in the
wedge socket (Fig. 13, item 3) and the
drum flange hole (Fig. 13, item 7).
• Remove the wire rope.
-> Disassembly completed.
Procedure for installing new wire rope per
figure 14.
Start by running the end of the wire rope
through the opening of the limit stop lever
(Fig. 13, item 10), then sliding it around the
drum.
30

Publicidad

Tabla de contenido
loading

Tabla de contenido