At high liquid velocities (greater than 5 m/s), we
recommend that you to fit larger expansion joints
matching the pipes.
Expansion joints
Fig. 12
TP pump installed with larger expansion
joints

5.3 Foundation

We recommend that you install the pump on a
concrete foundation which is heavy enough to
provide permanent and rigid support to the entire
pump. The foundation must be capable of absorbing
any vibration, normal strain or shock. As a rule of
thumb, the weight of the concrete foundation must
be 1.5 times the weight of the pump. Place the pump
on the foundation and fasten it. See fig. 11.
5.3.1 Recommended concrete foundations for TP,
TPD Series 300 pumps
For TP Series 300 pumps with weights of 150 kg or
more, we recommend that you mount the pump on a
concrete foundation with the dimensions stated in
the table below. The same recommendation applies
for TPD Series 300 pumps with weights of 300 kg or
more.
Fig. 13
Foundation for TP, TPD Series 300
pumps
10
Concrete foundation dimensions
Pump weight
(height)
[kg]
[mm]
150
280
200
310
250
330
300
360
350
375
400
390
450
410
500
420
550
440
600
450
650
460
700
470
750
480
800
490
850
500
900
510
≤ DN 200
950
520
1000
530
1050
540
1100
550
1150
560
1200
560
1250
570
1300
580
1350
590
1400
600
1450
600
1500
610
1550
620
1600
620
1650
630
1700
635
Y
Z
X
(length)
(width)
[mm]
[mm]
565
565
620
620
670
670
710
710
750
750
780
780
810
810
840
840
870
870
900
900
920
920
940
940
970
970
990
990
1010
1010
1030
1030
1050
1050
1060
1060
1080
1080
1100
1100
1100
1100
1130
1130
1150
1150
1160
1160
1180
1180
1190
1190
1200
1200
1220
1220
1230
1230
1250
1250
1250
1250
1270
1270