Charging - Porsche Mobile Charger Plus Manual De Funcionamiento E Instrucciones De Instalación

Ocultar thumbs Ver también para Mobile Charger Plus:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
C
Press the
button to select
HARGE STATUS
a charging power of 50 % or 100 % or to change to
energy manager mode. If you have an energy
manager, in this mode a connection to the energy
manager is established and its configured charging
power is used.
M
Press the
, sometimes in
ULTIFUNCTION BUTTON
combination with other buttons, to set the following
device functions:
– Skip reconnection to the energy manager
– Deactivate and activate ground monitoring
– Reset to factory settings
– Reset residual current device error
Buttons A and F and light indicators B – E display the
operating state of the control unit and possible errors
by means of different colors, lights, and flashing.
f Please see chapter "Malfunctions" on page 16.
f Please see chapter "Charging current limiting" on
page 11.

Charging

Vehicle charge port
Electric shock, fire
DANGER
Risk of serious or fatal injury due to fire or electric
shock.
e Always observe the specified sequence for the
charging process.
e Do not disconnect the vehicle cable from the
vehicle charge port during the charging process.
e End the charging process before disconnecting
the vehicle cable from the vehicle charge port.
e Do not disconnect the charger from the electrical
socket during the charging process.
Errors are indicated by the red light indicators.
f Please see chapter "Malfunctions" on page 16.
f Read the Owner's Manual for information on
connecting and disconnecting the vehicle cable
to and from the vehicle charge port and for the
charging and connection status of the vehicle
charge port.
Charging current limiting
The maximum available charging current is
determined by the types of cable that are connected.
The charger detects the voltage and the available
electric current automatically.
The charging current can also be reduced by other
electrical loads in the home network, e.g. electric
heating or hot water systems.
If you are unsure about this, contact a qualified
electrician.
In chargers with house connection, the charging
current is automatically limited to 50 % on delivery to
prevent overheating of the electrical installation.
You can manually adjust the power used for charging
C
via the
button. If the charger is
HARGE STATUS
connected to the energy manager, this takes over
control.
Getting started
The charger performs a self-test on connection to
the power grid.
e Insert the plug into the electrical socket.
Following a successful self-test:
C
The
button lights up
HARGE STATUS
white.
– The charger is set to the same charging power
as the previous charging session.
50 %
100 %
The
,
or
and
indicator lights up.
The charger is ready for operation.
Selecting the charge status
Fig. 10: Selecting the charge status
This allows you to select whether the charger should
be limited to maximum 50 % or 100 % of the
available charging power. If you have an energy
manager, you can select whether this should set
the charging power.
b The charger is ready for operation.
e
Press and hold the
3 seconds.
The charger switches to a different charge status
50 %
100 %
(
,
relevant light indicator lights up.
If the energy manager charge status is activated,
the
light indicator lights up yellow and
50 %
the
charge status lights up green. If the
energy manager cuts out during operation,
the charger switches to the
To enable the charger to be controlled by the energy
manager, it must be connected to the same PLC
50 %
light
network.
f Please see chapter "Producing a connection to
the charger" on page 14.
Operating instructions
C
button for
HARGE STATUS
, or energy manager) and the
50 %
charge status.