Operating instructions
GB
Dear Customer,
Congratulation on purchasing
your new STEINEL sensor and
thank you for the confidence
you have shown in us. You have
chosen a high-quality product
that has been manufactured,
tested and packed with the
greatest care.

Safety warnings

í Disconnect the power supply
before attempting any work
on the sensor!
í During installation, the elec-
tric power cable to be con-
nected must be dead. There-
fore, switch 'OFF' the power
first and use a voltage tester
to make sure the wiring is off
circuit.

Assembly/Installation

The sensor is only intended for
concealed, indoor installation in
ceilings (apart from the COM 1
AP - surface-mounted - option).
A clamping-type ceiling adapter
or surface-mounting adapter is
not included.

System components

Load module
Sensor module
Sensor base
Dip switches
(1) Normal/test mode
(2) Semi-/fully automatic mode
(3) Button/switch
(4) 'ON' / 'ON'-'OFF' button
(5) DIM option
Constant lighting control
'ON'/'OFF'
Please familiarise yourself with
these instructions before
attempting to install the product
because prolonged, reliable and
trouble-free operation will only
be ensured if it is fitted and used
properly.
í Installing the sensor involves
work on the mains power
supply. This work must there-
fore be carried out profes-
sionally in accordance with
the applicable national wir-
ing regulations and electrical
operating conditions (VDE
0100).
(see chart on page 2)
Sensor and load module come
ready assembled and must be
plugged together after fitting
the load module and setting the
potentiometers/dip switches.
The sensor module must then
be locked in position at the
catch mechanism
, using a
screwdriver if necessary.
Twilight setting
Time setting
Switching output 1
HVAC stay-'ON' time
Switching output 2
HVAC switch-'ON' delay
Switching output 2
Reach setting
k
Kaiser stud-wall junction box,
1 0.
1
optional
- 20 -
We hope your new STEINEL
sensor will bring you lasting
pleasure.
í Terminal B 1, B 2 is a switch-
ing contact for low-energy
circuits, no higher than 1 A.
This must be provided with
appropriate fuse protection.
í Control output DIM 1-10 V
must only be used for con-
necting electronic ballasts
with electrically isolated
control signal.
Accessories:
Kaiser junction box for stud walls
EAN no.: 4007841 000370
Clamping-type ceiling adapter
EAN no. 4007841 002855
Surface-mounting adapter,
EAN no.: 4007841 000363
Guard cage,
EAN no.: 4007841 003036
Service remote control,
EAN no.: 4007841 000387
User remote control,
EAN no.: 4007841 003012
k
Clamping-type ceiling adapter,
1 0.
2
optional
Surface-mounting adapter
IP 54, optional
Locking mechanism
Assembly/Installation
Parallel-connected
configurations
Stay-'ON' time
Orientation light
DIM option