EdmoLift Products Manual
Bolting down the Armlift
All models of the EdmoLift Armlifts must be fixed to the floor/ground.
Installation of the Armlift.
All models of EdmoLift Armlifts must be fixed to the floor/ground by means of expander bolts or similar. Due to the
movement pattern of the platform the Armlift must be placed on top of the floor/ground i.e. not recessed in a pit.
Installation:
1. The base frame of the Armlift is not as standard self-supporting. It is important that the floor/ground is flat and stable
and that the installation area, when necessary, is well drained. Remember that the Arm Lift has an extensive motion
area so that neither the Armlift, nor the load can come in contact with other working equipment, transportation aisles,
machines or walls. See below.
2. Raise the lift and chock the mechanism. See picture on page 39.
3. Place the Armlift in the desired location. Turn the tilting side towards the position where the goods will be handled.
See picture below.
4. Make a trial run. Adjust lowering speed if desired. The maximum lowering and platform peripheral speed must not
exceed 100mm/s. with full load.
5. Test the safety frame operation on all sides. Adjust if necessary.
6. The control box should be positioned so that the operator has a clear view over the lift and the load when the Armlift
is operated.
7. Fasten the Armlift to the floor/ground with expander bolts or similar. See above.
8. Check that all cables and the hydraulic hose to the remote power pack are placed so that there is no risk of
damage.
Motion area of the Armlift
The Armlift has a large motion area. It is very important to arrange the
operation area so that neither the lift nor the load can interfere with
other working areas, transportation aisles, machines or parts of the
building. The control position must be chosen so that persons do not
stay within the motion area of the machine or the load or when goods
might fall of the load carrier.
NOTE! The platform has a sideways movement up to 440mm,
depending on the lift stroke.
F
F
Copyright © EdmoLift AB 2004-2007
All rights reserved. No part of this publication may be reproduced, stored in a retrie-
val system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the permission of the publisher.
Type
AL, ALT, ART 750
AL, ALT 1500
ART 1500
ALT, ART 3000
F
F
2005-02-01
5°
45°
F = Torque kN
6.5
12.1
13.1
13.1
EdmoLift AB
Jägaregatan 11
S-871 42 HÄRNÖSAND, SWEDEN
85921 GB
440
No. of expanding
bolts
4
4
4
6
Tfn. +46 (0)611-83 780
41
Fax. +46 (0)611-51 15 80
info@edmolift.se