EdmoLift Products Manual
Bolting down the Tilt
All EdmoLift Tilt models must be fixed to the floor/ground.
Installation of the Tilt.
All EdmoLift Tilt models must be fixed to the floor/ground by means of expander bolts or similar. Due to the
movement pattern of the platform the tilt must be positioned on top of the floor/ground i.e. not recessed in a pit.
Installing:
1. The base frame of the tilt is not as standard self supporting. It is important that the flooring is flat and stable and
that the installation area or pit, if necessary, is well drained.
As the Tilt has a large motion area it is very important to arrange the operation area so that neither the lift nor the
load can interfere with other working areas, transportation aisles, machines or parts of the building..
2. Raise the lift and chock the mechanism.
3. Place the Tilt in the desired location. Turn the tilting side towards the position where the goods will be handled.
See picture below.
4. Make a trial run. Adjust lowering speed if desired. The maximum lowering and platform peripheral speed must
not exceed 100mm/s. with full load.
5. Test the safety frame operation on all sides. Adjust if necessary
6. The control box should be positioned so that the operator has a clear view over the lift and the load when the
Tilt is operated.
7. Fasten the tilt to the floor/ground with expander bolts or similar. See below.
8. Check that all cables and the hydraulic hose to the remote power pack are placed so that there is no risk of
damage.
Type
F = Torque kN
6.5
6.5
13
12.1
18
13.1
Copyright © EdmoLift AB 2004-2007
All rights reserved. No part of this publication may be reproduced, stored in a retrie-
44
val system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the permission of the publisher.
No. of expander bolts
6xM12
6xM12
6xM12
EdmoLift AB
Jägaregatan 11
S-871 42 HÄRNÖSAND, SWEDEN
85921 GB
2005-02-01
Tfn. +46 (0)611-83 780
Fax. +46 (0)611-51 15 80
info@edmolift.se