EdmoLift Products Manual
Construction of Lift Table, Armlift, Tilt, and Pallet Lift
Hydraulic system
EdmoLift hydraulic lifts have, as standard, an integral or remote electro hydraulic power pack. Remote power packs
can be supplied to meet specific applications. The hydraulic system is single acting and as standard in accordance
with the enclosed hydraulic diagram. The remote power pack is connected to the lift by the hydraulic hose (standard
length 3m) supplied with the lift.
The power unit must be stood on its base and the control box must be placed so that the operator has a clear view
of the movement of the lift and its load at all times. Due to the versatility of the lift it is quite common for the hydraulic
system to be adapted to suit individual requirements.
In such cases, the appropriate hydraulic diagram is included at time of delivery.
Type II systems are provided with a check valve on the cylinder
To obtain optimum performance from the hydraulic system, always make sure that :
* Correct oil type is used.
* The hydraulic system is clean
Electrical system
Check before connecting the lift to the mains supply, that the motor and electrical box voltages conform with
the mains voltage.
NOTE! Electrical installation, and possible fault finding, must be carried out by a competent electrician.
Unless another option has been supplied, the Lift Table is supplied for connection to 3-phase/400V/50Hz. (For 380-
420V). Changing to 3-phase/ 230V/50Hz (220-240V) can be made by means of a re-connection in the motor junction
box, (see label in the junction box for correct position of the plates) and switching of fuses in the electrical equipment
and re-connection of the transformer.
The electrical box, located in the Lift Table power pack or in the remote power pack, contains a motor contactor,
transformer with rectifier for 24V DC feed to the control system, fuses for the primary and secondary wirings of the
transformer and junctions (incl. spare connections for limit switches and other possible options).
The mains isolator is not supplied by EdmoLift, but must be fitted by the electrician at time of installation.
The feed cable is to be connected to the isolator junctions.
The electrical wiring diagram is included in the electrical box and is also included in this manual.
Due to the versatility of Lift Tables it is quite common for the electrical system to be individually adapted. The specific
electrical circuit diagram is then included at time of delivery.
Copyright © EdmoLift AB 2004-2007
All rights reserved. No part of this publication may be reproduced, stored in a retrie-
val system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the permission of the publisher.
2005-02-01
EdmoLift AB
Jägaregatan 11
S-871 42 HÄRNÖSAND, SWEDEN
85921 GB
Tfn. +46 (0)611-83 780
45
Fax. +46 (0)611-51 15 80
info@edmolift.se